Hide Floor Jack Shims (Enclosed Wood Baseboard Box)

Store only unloaded floor-jack shims in a shallow, removable wood box that looks like a baseboard. Keep the jack, its footing, and every structural support outside the enclosure and easy to inspect. Measure the shims and opening for a hand-sized fit, fasten the box to framing, and never let it carry building or jack loads.

If you have pets, loose wood shims can be tempting to chew or carry off. A covered storage spot helps keep them out of reach, but the cover must still open easily when you need a shim. The goal is a tidy, baseboard-style enclosure for stored, unloaded shims, not a way to hide a working jack or support.

I treat this as a small storage project with a firm boundary: the box is cosmetic and nonstructural. Before building, I check what the jack supports, where its load travels, and whether any wiring, pipe, vent, or service point is nearby. If the area is part of an active support setup, stop and resolve that issue first.

Planning and Load-Path Survey

A load path is the route that weight takes through a structure, from the floor or beam down to its supports. Surveying it means identifying the jack, its footing, nearby posts or beams, and the floor framing before deciding where a storage box can go. The box must sit outside that working system.

Start by identifying whether the jack is in use, what it contacts, and what it may support. Follow the visible structure around it. If you cannot tell whether a post, beam, or jack is carrying building load, do not cover it; ask a qualified building professional to assess it.

Next, locate the floor framing and check for utilities or openings in the planned box area. Do not assume the space behind an existing baseboard is clear. A stud finder can help locate framing, but it does not confirm the absence of every pipe or wire. Inspect carefully, and use appropriate plans or professional help when the location is uncertain.

Measure the largest shim and the bundle as stored. Add at least ⅛ inch of clearance around the bundle as a fit allowance; increase it if the shims are irregular, damp, or hard to grip. This is not a building-code dimension. It is a practical starting point for avoiding a jammed box.

Survey itemWhat to checkStop if…
Jack and footingPosition, operating area, and manufacturer’s clearance instructionsThe box would touch or obstruct the jack
StructureNearby post, beam, or other supportThe box would hide or brace a support
FloorJoist direction and planned fastening pointsYou cannot confirm a safe fastening location
ServicesWiring, pipes, vents, and access pointsThe enclosure would cover or restrict them
ShimsBundle size and largest individual shimThe opening will not allow easy removal

The jack, its base, and any structural support must remain independently stable and visible enough to inspect. Do not box in an active jack, a loaded shim stack, or a post. A cover does not make temporary equipment a permanent support.

Access, Jack Clearance, and Services

Access means being able to inspect the stored shims and remove them without taking apart fixed trim. Jack clearance means the cover does not enter the jack’s footprint or operating space. Both matter: a neat-looking face is not a good solution if it blocks equipment, required service access, or retrieval.

Set the box fully outside the jack’s footprint and operating envelope. Follow the jack manufacturer’s instructions for operation and clearance. Do not let the enclosure bear on the jack, its footing, a beam, or a post, and do not use it to brace any of them.

Plan the opening around the largest shim and the user’s hand. A fully removable panel or lift-off face usually makes inspection straightforward. A hinged face can also work if it opens fully and does not strike the jack or nearby objects. Avoid a fixed face that requires removal of permanent trim to reach the contents.

Keep the box away from anything it must not cover. This includes combustion-air openings, vents, electrical equipment, and required service openings. No universal airflow rate applies to ordinary dry wood-shim storage, but that does not permit blocking ventilation or equipment. If a vent or service point is nearby, preserve its full required access and clearance.

Store only dry shims. If they are damp, let them dry before putting them away; a tight enclosure is not a drying cabinet. Check that the bundle can be lifted out without snagging or forcing the cover. The access test is simple: open the face, inspect the contents, and remove the largest shim by hand.

Nonstructural Box Construction and Finish

A nonstructural box is a light enclosure that stores items but does not support a building, jack, or other load. For a baseboard-style shim box, a shallow frame and removable plywood face can create a clean finish. The panels attach to framing; the box does not become part of the support system.

A practical starting material is ¾-inch plywood for the enclosure panels. This is a construction choice, not a code minimum. Size the frame to the measured shim bundle, the clearance allowance, and the hand-sized opening. Keep the interior plain so shims do not catch on cleats or fasteners.

Fasten panels to wood framing, not just to finish flooring or trim. #8 × 1¼-inch wood screws are a workable starting point for fastening ¾-inch plywood to wood framing. Before driving screws, confirm they will not hit concealed wiring or piping or break through a finished surface. Adjust screw length or fastening location as needed.

For the face, use removable screws, a lift-off panel, or a hinge that allows full access. Choose a fastening method you can operate without damaging the surrounding trim. If you add a latch, make sure it does not make the panel difficult to open or prevent a clear view of the contents.

Finish the outside to match nearby baseboard, but do not seal over a vent, electrical equipment, or service opening. Keep the box separate from the jack and any support. A baseboard appearance is a finish detail, not permission to conceal structural equipment.

Retrieval, Inspection, and Final Verification

Final verification is a hands-on check that the enclosure stays separate from structural loads, opens as planned, and allows the shims to be inspected and removed. It also confirms that the cover does not interfere with nearby equipment or services. Do this before treating the job as complete, then repeat the access check after changes nearby.

Use this sequence:

  1. Dry-fit the frame and panels. Confirm the enclosure sits outside the jack’s footprint and operating envelope. Check that it does not touch or brace the jack, its footing, a post, or a beam.
  2. Check the fastening points. Confirm framing locations and make sure screw paths will not hit concealed utilities or damage finished surfaces.
  3. Install the enclosure. Fasten the panels to framing. Keep the face removable or fully hinged; do not permanently seal it.
  4. Test access. Open the cover, inspect the shim bundle, and remove the largest shim. If removal requires tools or the shims snag, enlarge or adjust the access.
  5. Check for interference. Confirm the enclosure does not block a vent, electrical equipment, a service opening, or jack operation.
  6. Check stability. The box should not rock or carry floor load. If it moves, contacts a support, or seems to affect the floor or jack, stop and correct the installation before use.

There is no universal code size for a small shim-storage enclosure. Local requirements may apply to the surrounding structure, utilities, or access points, so do not treat this guide as approval to alter those systems. If building support or a load path is uncertain, get an appropriate assessment before adding trim or a box.

Practical Site Scenarios

These are planning examples, not reports of documented projects. They show how the same rules apply in two common layouts: a clear wall area near a jack, and a tight area where services or support elements limit the available space. In either case, the enclosure stores shims only and does not change how the structure is supported.

Open wall beside a jack: The proposed box fits along a baseboard, outside the jack’s footprint. After checking the framing and services, the installer sizes the opening to the largest shim and hand, then uses a removable face. The final check confirms that shims come out freely and the box does not touch the jack or its footing.

Crowded corner near a post: The only visually convenient location is beside a structural post, but a box there would hide part of the support or restrict inspection. The right response is not to wrap the post in trim. Move shim storage to a separate clear location, or choose another storage method that leaves the post visible and accessible.

These examples point to a useful rule: choose the location for safe separation and access first, then make the finish blend in. If appearance and inspection conflict, preserve inspection.

Conclusion

A baseboard-style enclosure can keep unloaded floor-jack shims organized and out of sight, including from curious pets, without hiding the equipment that matters. Measure the bundle, allow at least ⅛ inch of fit clearance, provide a hand-sized removable opening, and attach the box to framing. Keep it entirely separate from the jack, its footing, and every structural support.

Before finishing, open the face, retrieve the largest shim, and check the jack, nearby services, and support elements remain clear. When the load path or local requirements are uncertain, do not conceal the area until it has been assessed.

Frequently Asked Questions

Can I put a wood box around a floor jack?
No. This design is for stored, unloaded shims only. Keep an operating jack, its footing, and any support visible and accessible.

Can the box touch a jack or post if it carries no weight?
Avoid contact. The enclosure should stay outside the jack’s footprint and operating area and should not brace or obscure a post, beam, or other support.

How much clearance should I leave around the shims?
Allow at least ⅛ inch around the stored bundle as a fit allowance. Increase that space if shims are irregular, damp, or difficult to remove.

What plywood thickness can I use?
¾-inch plywood is a practical panel choice for this small enclosure. It is not a code-mandated minimum; fasten it to framing and design the box so it carries no structural load.

What screws are a reasonable starting point?

8 × 1¼-inch wood screws can work for fastening ¾-inch plywood to wood framing. Check for concealed wiring or piping and avoid damage to finished surfaces before fastening.

Does a shim-storage box need ventilation?
There is no prescribed airflow rate for ordinary dry wood-shim storage. Do not cover a vent, combustion-air opening, electrical equipment, or required service access.

Can I use a permanently fixed baseboard face?
Not if it prevents inspection or retrieval. Use a fully removable panel or a hinge that opens far enough to inspect and remove the shims without dismantling fixed trim.

Can I store damp shims in the enclosure?
No. Let them dry first. The enclosure is for storage, not for drying damp wood.

What if a post is in the best location for the box?
Do not hide the post. Choose another location that keeps the support visible and accessible, or use a different storage arrangement.

Is a boxed-in jack a permanent building support?
No. A cosmetic enclosure does not make a jack or temporary prop suitable as permanent support. Permanent structural support or alteration needs a design suited to the loads and local code.

(This article was written by one of our staff writers, Michael Donovan. Visit our Meet the Team page.)